Capnoedge

Single-use colorimetric CO₂ detector.

One device from general pediatric to adult use.

Placed in the breathing circuit and read against a printed reference on the product.

At a glance.

The key figures. Full detail in the specifications below.

≥ 18 lb(8 kg)

Patient weight. From approximately 6–7 months.

2 cmH₂O

Resistance to flow at 60 L/min.

11 mL

Internal dead space.

22 / 15 mm

Patient end. 22 mm OD / 15 mm ID.

15 mm

Circuit end. 15 mm OD.

Single use.
No calibration.

Passive device, no power supply.

How it works.

Three steps, no equipment.

Step 1

Standard connections.

  • Patient end, 22 mm OD / 15 mm ID. Connects to an endotracheal tube or a face mask.
  • Circuit end, 15 mm OD. Connects to the manual resuscitator or breathing circuit.
Step 2

Ventilate.

The indicator changes color with the CO₂ in the exhaled gas. Read it against the scale printed on the device.

Step 3

Read after six breaths.

Compare the indicator color with the printed reference scale at the end of expiration.

Blue, < 0.5 % CO₂
No or low CO₂ level
Yellow, ~5 % CO₂
Adequate CO₂ level
  • ~5
  • ~2
  • ~1
  • < 0.5

In use.

Between the airway device and the breathing circuit.

Between face mask and manual resuscitator
Inline on a manual resuscitator
Endotracheal tube on a manual resuscitator

Watch.

A short animation of how Capnoedge works.

How Capnoedge works Air in, CO₂ in return, the indicator detects presence of CO₂ from approx. < 0.5 % to ~5 %.

Specifications.

Capnoedge technical specification
ParameterValueCondition / note
Use
Patient weight≥ 18 lb (8 kg)From approximately 6–7 months, pediatric to adult
Single useYes
Physical
Connector port – patient end22 mm OD / 15 mm ID22 mm outer diameter, 15 mm inner diameter
Connector port – circuit end15 mm OD15 mm outer diameter
Internal dead space11 mL
Device weight0.32 oz (9 g)
Performance
Resistance to flow2 cmH₂OAt 60 L/min
Breath-to-breath visualizationUp to about 30 breaths/min
Power supplyNonePassive device
CalibrationNot required
HumidityHumidity tolerant
Storage
Storage temperature14 °F to 86 °F (−10 °C to 30 °C)
Materials and compatibility
SterilityNon-Sterile
LatexLatex-freeNot made with Natural Rubber Latex.

Instructions for Use and technical documentation are available on request from Mincor AB. Request information

Regulatory status.

Capnoedge is pending regulatory clearance and is not currently available for patient use or sale. For information, contact Mincor AB at info@mincor.se.

Questions about Capnoedge?

Get in touch with Mincor AB at info@mincor.se.

Contact
‹ Capnoedge

Get in touch.

Questions about Capnoedge and its specification? Get in touch with Mincor AB at info@mincor.se.

Mincor AB

Stockholm, Sweden

Addressc/o Ekonomibolaget, Kommendörsgatan 28, 114 48 Stockholm, Sweden
Email Mincor

Opens your email program with the address filled in.

What can we help with?

Manufacturer

Company
Mincor AB
Registered office
Stockholm, Sweden
Organisationsnummer
556569-6274
Legal manufacturer
Mincor AB
‹ Capnoedge

Privacy.

Last updated 3 November 2026

Who is responsible

Mincor AB, organisationsnummer 556569-6274, c/o Ekonomibolaget, Kommendörsgatan 28, 114 48 Stockholm, Sweden, is the controller for the personal data described here. Contact info@mincor.se.

What this website collects

This website has no forms, no user accounts, no newsletter, no analytics and no cookies. When you visit it, our hosting provider, Netlify, Inc., records technical data in server logs: IP address, time of the request, the page requested and browser information.

Transfers outside the EU

Netlify is based in the United States, so these server logs may be processed there. Netlify processes them on our behalf under a data processing agreement and is certified under the EU–U.S. Data Privacy Framework, which the European Commission has found provides an adequate level of protection.

Why, and on what legal basis

The server logs are used only to deliver and secure the website. The legal basis is our legitimate interest in operating a secure website (Article 6(1)(f) GDPR).

How long it is kept

Server logs are kept only as long as needed for these purposes and are then deleted in line with our hosting provider’s routines.

If you email us

If you contact us by email, we use your name, email address and message to reply. We keep the correspondence as long as needed to handle your inquiry and to meet legal obligations, such as bookkeeping rules.

Your rights

You have the right to request access to, correction or erasure of your personal data, and to restrict or object to its processing. Contact us at the address above.

You also have the right to lodge a complaint with the Swedish Authority for Privacy Protection (Integritetsskyddsmyndigheten, IMY), imy.se.